Static Overvoltage Setting Without High-Voltage Output! Prevent Accidental Voltage Boost and Test Sample Breakdown

In high-voltage electrical tests, overvoltage breakdown of the test object is a safety incident that all high-voltage test personnel must guard against at all times. For example, during handover DC withstand voltage tests on 10kV or 35kV power cables, specifications impose strict upper limits for the maximum test voltage (such as 25kV or 40kV). If technicians are distracted, misread the meter scale, or turn the fine adjustment knob too rapidly on site, the output voltage may exceed the insulation withstand limit of the test sample. The insulation core can break down within tens of milliseconds, resulting in scrapping of expensive cables.

On many conventional DC high-voltage generators, to set the overvoltage protection value, operators have to disconnect the test sample, ramp up the regulator to the protection trigger point under no-load high voltage, and let the instrument trip once to calibrate the threshold. This outdated method of calibrating overvoltage with live high voltage is not only cumbersome and exposes users to electric shock hazards, but also may damage the internal relay of the instrument due to misoperation on site.

To realize safe and convenient preset overvoltage protection, the HZZGF DC High Voltage Generator manufactured by Baoding Huazheng Electric Manufacturing Co., Ltd. adopts the innovative static zero-voltage overvoltage calibration technology.

Static Presetting without Boosting Voltage, Error Strictly Controlled within 1% The HZZGF series is equipped with a concealed 【Overvoltage Setting Knob】 on the right side of the control panel: Safe zero-voltage static setting: When the high-voltage green indicator is off (high-voltage switch disconnected), press and hold the 【MOA 75%】 button for more than 3 seconds until the audible prompt stops, and the control box enters the static overvoltage calibration mode. Real-time threshold display on voltmeter: No dangerous high voltage is present at the high-voltage terminals. Operators only need to fine-tune the concealed potentiometer knob with a small screwdriver, and the digital voltmeter on the front of the control box directly displays the preset maximum protection voltage in real time (e.g. accurately set to 25.0kV). Calibration accuracy better than 1%: Stepless arbitrary setting within the rated voltage range, with an overvoltage calibration error of only 1%. Automatic switch to measured value after voltage application: After setting, turn the potentiometer back to zero and close the high-voltage switch. The green indicator lights up to enter the voltage boosting state, and the voltmeter automatically switches seamlessly to display the actual output voltage. Millisecond-level overvoltage lockout and cutoff: During the test, if the output voltage accidentally exceeds the preset value due to any disturbance, the internal comparison circuit sends a trip signal within microseconds. The red overvoltage indicator lights up, the high-voltage output is forcibly cut off instantly with a buzzer alarm, reliably protecting the test sample from overvoltage damage.

Static calibration, zero-voltage safety, microsecond protection. HZZGF eliminates the old risks of live trial calibration for overvoltage protection and provides a reliable safety guarantee for on-site high-voltage tests.