Products
High Voltage Test Set
Thank you for choosing CS2674AX Withstanding Voltage lnstrument.
We hope that this instrument can make your work easier and more enjoyable, so that you can get the feeling of office automation in the test and analysis work.
Its main business is the production, manufacture and sales of electrical equipment and testing instruments.
Function introduction
(1)Check the input power connection
To ensure operator safety, the hipot tester’s shell is ground I type of work, but when the input power supply is with wrong polarity (correct connection is that the left is neutral, the right is phase and the upper is ground), the shell may be with electric and cause danger. The hipot tester comes with power safety detection function, there is an "OK" indicator lamp on the front panel, if the "OK" indicator both lights, power input is correct, you can press the start button, if either “o” or “k” not bright, the input power is error, please do not start the hipot tester and check the input power supply.
(2)Timer
When the test time is set (greater than 0), after the test is begun, the counter will begin to reverse, after the time value reached 0,the tester will cut off the output voltage automatically. When the test time is set to "0.0s", the tester will continue testing until user presses the "STOP" button or set the “reset” signal enable. Anyway, whether it is time testing or continuous testing, users can stop the tester by pressing the "STOP" button or enable the “reset” signal .
(3)Remote interface、PLC interface
This hipot tester can be equipped with remote control gun or the PLC interface to start or reset.
(4)Danger indicator
To ensure operator safety, the danger indicator will be lit if there is high voltage. After the hipot tester starts to test, If the output voltage is lower than the setting voltage, the danger indicator will flash. If the output voltage is higher than the set voltage, the danger indicator will bright normally. Even the withstanding voltage tester is in the stop status, if high voltage output is larger than the setting voltage, the danger indicator will light to warn there is high voltage output, users should not contact any object in the H.V output ports to prevent electric shock.
Specifications
This chapter introduces the technical parameters of various testers in detail.
Model | CS2674AX | ||
A C W | Output voltage range | (0.00~20.00)kV | |
Maximum output power | 200VA | ||
Maximum rated current | 10mA | ||
Current gear | 2mA、10mA | ||
Output waveform | Sine wave | ||
Output waveform distortion | ≤5% | ||
Testing time | 0.0s~999s 0.0=continuous test | ||
D C W | Output voltage range | (0.00~20.00)kV | |
Maximum output power | 200VA | ||
Maximum rated current | 10mA | ||
Current gear | 2mA、10mA | ||
Ripple factor | ≤5% | ||
Testing time | 0.0s~999s 0.0=continuous test | ||
Voltmeter | Range | (0.00~20.00)kV | |
Accuracy | ±(5%+3dgt) | ||
Resolution | 10V | ||
Display value | Root mean square | ||
Ammeter | Measuring range | AC | 0.100mA ~ 10.00mA |
DC | 0.100mA ~ 10.00mA | ||
Resolution | 2mA Gear:1uA,10mA Gear:10uA | ||
Measurement Accuracy | ±(5%+3dgt) | ||
Timer | Range | 0.0s~999s | |
Minimum Resolution | 0.1s | ||
Accuracy | ±(1%+50ms) | ||
PLC interface | Yes | ||
Remote control interface | Yes |